Can be used without issues in a standard configuration
Cube Case Temperature Evaluation Test

Additional thermal countermeasures using a heatsink panel are also available

A camera was installed inside the cube case, and an evaluation test was conducted under conditions using a heatsink structural panel to assess the internal temperature changes of the enclosure as well as the heat dissipation performance of the heatsink panel.

Do you have any of these concerns?

Will heat build up inside the enclosure?
Is it suitable for long-term operation?
Is a heatsink necessary?

Test Results

Stable operation is possible under typical conditions even with the standard configuration.

CPU Temperature: Within acceptable range
Internal Temperature: No issues detected

Further temperature reduction is possible with a heatsink panel.

For operation under higher loads or in high-temperature environments, where thermal stability may be a concern, using a heatsink panel can provide an effective solution.

Test Conditions: 2.64 W Industrial Camera

Heatsink Panels: 1 piece

Cooling Structure

ComponentsSpecifications
External Heatsink: 1 pieceMaterial: AL6063
Fin Height: 15 mm
Fin Pitch: 5.25 mm
Base Thickness: 4.5 mm
Internal FanSunon MF30151V3-1000C-A99 20mA

Heatsink Panels: 3 pieces

Cooling Structure

ComponentsSpecifications
External Heatsink: 3 pieceMaterial: AL6063
Fin Height: 15 mm
Fin Pitch: 5.25 mm
Base Thickness: 4.5 mm
Internal FanSunon MF30151V3-1000C-A99 20mA

Test Environment

8-tatami Western-style room. Window opened approximately 10 cm.
When the room temperature rose, the air conditioner was operated (set to 30°C, low fan speed).

Equipment Used

ItemDetails
CameraSIP-K676K5
Image SensorSONY IMX676
ProcessorHi3519DV500
Camera Power Consumption2.64 W
PoE BoardXR-PM3812AT
PoE Board Power ConsumptionApprox.0.3 W
Total System Power ConsumptionApprox.2.9 W
Cube CaseCube Case 100

Measurement Results

Measurement ItemTemperature Range
Ambient Temperature18〜31℃
Inside Housing32〜43℃
CPU Area37〜51℃

Based on the Measurement Results

The results confirm that the internal temperature of the enclosure remains approximately +13°C higher than the ambient temperature.

Additionally, similar results were obtained when increasing the number of heatsink panels from one to three.

From this, it can be concluded that under the test conditions, a single heatsink panel provides sufficient heat dissipation performance.

For systems with higher heat generation, further improvement in thermal performance can be expected by increasing the number of heatsink panels.

Request a Quote / Contact Us

f you would like a quotation based on product pricing or order quantity, please contact us here.
We will propose the optimal configuration tailored to your specific application and requirements.